to series Pilkington Suncool®
to series Pilkington Suncool®

Pilkington
Suncool® One 60/40

Architectural glass with a perfect balance of light transmission and sun protection

Suitable for buildings with large glazed spaces - winter gardens or spacious lobbies. 

The low internal reflectivity provides a clear view from the inside of the room, and the excellent solar control performance makes this glass an excellent choice for south or southwest facing façades.

The product can be tempered, bend and laminated. Ceramic and organic paints can be used.

Advantages

  • Neutral shade

    Neutral shade

    The most neutral shade in reflected light and in the lumen

  • High light transmission

    High light transmission

    Lets a lot of natural light into the room

  • Solar protection

    Solar protection

    Blocks solar heat and maintains indoor comfort in summer

  • Protection from cold

    Protection from cold

    Blocks heat loss and maintains indoor comfort in winter
  • Saving

    Saving

    Helps to reduce air conditioning and heating costs

  • All types of processing

    All types of processing

    Tempering, molling, lamination, application of ceramic and organic paints

Indicators

LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 60 Light reflectance out, LRout, % 22 Light reflectance inside, LRin, % 14 Direct energy transmittance, DET, % 37 Energy reflectance, ER, % 30 Energy absorptance, EA, % 33 Solar factor, SF, % 40 Shading coefficient, SC, % 0.46 Ug-value (air-filled), W/m 2 К 1.0 Ug-value (argon-filled), W/m 2 К 0.68
Characteristics calculated for formula 6 | - 16 Ar - 4 Optifloat in accordance with GOST EN 410-2014, GOST EN 673-2016 (R0 for Moscow conditions using the STIS thermal calculator software).
LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 60 Light reflectance out, LRout, % 22 Light reflectance inside, LRin, % 14 Direct energy transmittance, DET, % 37 Energy reflectance, ER, % 30 Energy absorptance, EA, % 33 Solar factor, SF, % 40 Shading coefficient, SC, % 0.46 Ug-value (air-filled), W/m 2 К 1.3 Ug-value (argon-filled), W/m 2 К 1.0
All values are calculated for the central area of the IG unit 6| - 16 Ar - 4 according to EN 410 and EN 673 climatic conditions.

Technical data

  • Formats: Jumbo (6000 x 3210 mm), LES (2550 x 3210 mm)
  • Thickness: 4, 6, 8, 10, 12
  • Use in an IG Unit: required, coated inside
  • Must be hardened: possibly
  • Can be bent: possibly
  • Can be laminated: possibly
  • Decoration: application of ceramic and organic paints possible

Application area